{"id":3239,"date":"2019-05-27T11:36:00","date_gmt":"2019-05-27T09:36:00","guid":{"rendered":"https:\/\/mht-experience.ro\/?p=3239"},"modified":"2026-09-29T08:10:48","modified_gmt":"2026-09-29T06:10:48","slug":"mindspace-victoriei-tci-tower","status":"publish","type":"post","link":"https:\/\/mht-experience.ro\/en\/mindspace-victoriei-tci-tower\/","title":{"rendered":"Mindspace Victoriei TCI Tower"},"content":{"rendered":"\n<h1 id=\"h-instala\u021bii-electrice-mindspace-victoriei-tci-tower-execu\u021bie-integrata\" class=\"wp-block-heading\">Instala\u021bii electrice Mindspace Victoriei TCI Tower: execu\u021bie integrat\u0103<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">Cl\u0103dirile de birouri moderne nu tolereaz\u0103 erorile de execu\u021bie. Chiria\u0219ii cer confort vizual, re\u021bea stabil\u0103 \u0219i siguran\u021b\u0103 la incendiu. Toate acestea pornesc de la o instala\u021bie bine executat\u0103.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Proiectul Mindspace Victoriei TCI Tower a reunit aceste cerin\u021be. MHT Experience a executat instala\u021bii electrice Mindspace Victoriei \u0219i sistemele de curen\u021bi slabi \u00eentr-un singur pachet coordonat. Domeniul lucr\u0103rilor a acoperit dou\u0103 mari categorii.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solu\u021bii complete de instala\u021bii electrice<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Execu\u021bie instala\u021bii electrice<\/li>\n\n\n\n<li>Modific\u0103ri \u0219i complet\u0103ri tablouri electrice<\/li>\n\n\n\n<li>Iluminat \u0219i prize<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solu\u021bii complete de instala\u021bii de curen\u021bi slabi<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Cablare structurat\u0103<\/li>\n\n\n\n<li>Control acces<\/li>\n\n\n\n<li>Detec\u021bie incendiu<\/li>\n\n\n\n<li>Supraveghere video<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Un singur executant reduce interfe\u021bele dintre echipe. Scade riscul de conflicte \u00eentre trasee. Scurteaz\u0103 timpul de punere \u00een func\u021biune. Beneficiarul prime\u0219te un singur responsabil tehnic \u0219i un singur dosar de predare.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Utilizatorul final simte rezultatul \u00een fiecare zi. Lumina este uniform\u0103. Re\u021beaua nu cade. U\u0219ile r\u0103spund corect. Alarma func\u021bioneaz\u0103 la nevoie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Articolul detaliaz\u0103 resursele, solu\u021biile tehnice \u0219i normele aplicate. Valorile de proiectare provin din standardele \u00een vigoare. Parametrii finali au urmat documenta\u021bia proiectului.<\/p>\n\n\n\n<h2 id=\"h-managementul-tehnic-\u0219i-execu\u021bia-integrata-a-lucrarilor\" class=\"wp-block-heading\">Managementul tehnic \u0219i execu\u021bia integrat\u0103 a lucr\u0103rilor<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Execu\u021bia a mobilizat 1 inginer \u0219i 12 electricieni. Echipa a lucrat 3648 de ore \u00een total. Aceasta echivaleaz\u0103 cu 456 de zile-om de c\u00e2te 8 ore. Media teoretic\u0103 este de aproximativ 280,6 ore pe specialist.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Raportul de 12 electricieni la un inginer cere o coordonare foarte clar\u0103. Inginerul stabile\u0219te priorit\u0103\u021bile zilnice. Electricienii execut\u0103 pe fronturi de lucru delimitate. Tabelul de mai jos sintetizeaz\u0103 resursele.<\/p>\n\n\n\n<pre class=\"wp-block-preformatted\">text<code>+------------------------------+-------------+--------------------------+\n| Resurs\u0103                      | Cantitate   | Rol \u00een proiect           |\n+------------------------------+-------------+--------------------------+\n| Ingineri                     | 1           | Coordonare \u0219i verificare |\n| Electricieni                 | 12          | Execu\u021bie \u0219i montaj       |\n| Total speciali\u0219ti            | 13          | Echip\u0103 integrat\u0103         |\n| Ore lucrate (total)          | 3648 ore    | Toate activit\u0103\u021bile       |\n| Echivalent zile-om (8 h)     | 456 zile    | 3648 \/ 8                 |\n| Medie teoretic\u0103 \/ specialist | ~280,6 ore  | 3648 \/ 13                |\n+------------------------------+-------------+--------------------------+<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Matricea de alocare arat\u0103 cine r\u0103spunde de fiecare etap\u0103. Fiecare serviciu trece prin acelea\u0219i patru faze.<\/p>\n\n\n\n<pre class=\"wp-block-preformatted\">text<code>ACTIVITATE                        | PREG\u0102TIRE | MONTAJ | TESTARE \u0218I PIF | DOSAR\n----------------------------------+-----------+--------+----------------+------\nExecu\u021bie instala\u021bii electrice     |   I+E     |   E    |     I+E        |  I\nModific\u0103ri \u0219i complet\u0103ri tablouri |   I+E     |   E    |     I+E        |  I\nIluminat \u0219i prize                 |   I+E     |   E    |     I+E        |  I\nCablare structurat\u0103               |   I+E     |   E    |     I+E        |  I\nControl acces                     |   I+E     |   E    |     I+E        |  I\nDetec\u021bie incendiu                 |   I+E     |   E    |     I+E        |  I\nSupraveghere video                |   I+E     |   E    |     I+E        |  I\n\nI = inginer (coordonare, verificare, documenta\u021bie)\nE = electricieni (trasare, montaj, m\u0103sur\u0103tori)\nPIF = punere \u00een func\u021biune<\/code><\/pre>\n\n\n\n<h3 id=\"h-coordonarea-speciali\u0219tilor-\u0219i-rigoarea-de-execu\u021bie\" class=\"wp-block-heading\">Coordonarea speciali\u0219tilor \u0219i rigoarea de execu\u021bie<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Inginerul preia documenta\u021bia de proiect \u00eenainte de montaj. El verific\u0103 plan\u0219ele \u0219i breviarele de calcul. El identific\u0103 din timp interferen\u021bele cu structura, ventila\u021bia \u0219i finisajele.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Electricienii lucreaz\u0103 pe echipe de specialitate. O echip\u0103 execut\u0103 traseele \u0219i tubulatura. Alta monteaz\u0103 tablourile. A treia execut\u0103 cablarea \u0219i corpurile de iluminat. Sistemele de curen\u021bi slabi avanseaz\u0103 \u00een paralel, pe trasee separate.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ordinea lucr\u0103rilor urmeaz\u0103 o logic\u0103 fix\u0103. Mai \u00eent\u00e2i se execut\u0103 traseele \u0219i sus\u021binerile. Apoi se trag cablurile. Urmeaz\u0103 tablourile, aparatajul \u0219i corpurile de iluminat. La final se fac testele \u0219i punerea \u00een func\u021biune.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fiecare etap\u0103 produce documente verificabile. Lucr\u0103rile ascunse se recep\u021bioneaz\u0103 \u00eenainte de \u00eenchidere. Materialele au certificate CE \u0219i fi\u0219e tehnice. Cablurile respect\u0103 regulamentul european pentru produse de construc\u021bii (CPR).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Verific\u0103rile finale urmeaz\u0103 SR HD 60364-6. Se m\u0103soar\u0103 continuitatea conductoarelor de protec\u021bie. Se m\u0103soar\u0103 rezisten\u021ba de izola\u021bie. Se verific\u0103 impedan\u021ba buclei de defect. Se testeaz\u0103 declan\u0219area dispozitivelor diferen\u021biale.<\/p>\n\n\n\n<h4 id=\"h-standarde-de-securitate-a-muncii-\u0219i-dirigen\u021bie-pe-\u0219antier\" class=\"wp-block-heading\">Standarde de securitate a muncii \u0219i dirigen\u021bie pe \u0219antier<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Siguran\u021ba muncii este o condi\u021bie de execu\u021bie, nu o formalitate. MHT Experience aplic\u0103 un sistem certificat ISO 45001. Lucr\u0103rile la instala\u021bii existente cer proceduri stricte.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00cenainte de orice interven\u021bie se aplic\u0103 cele cinci reguli de siguran\u021b\u0103:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Circuitul se separ\u0103 complet de surs\u0103.<\/li>\n\n\n\n<li>Se blocheaz\u0103 \u00eempotriva reconect\u0103rii.<\/li>\n\n\n\n<li>Se verific\u0103 lipsa tensiunii.<\/li>\n\n\n\n<li>Se face legarea la p\u0103m\u00e2nt \u0219i \u00een scurtcircuit, unde este cazul.<\/li>\n\n\n\n<li>Se protejeaz\u0103 piesele vecine aflate sub tensiune.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Se folosesc scule izolate 1000 V, conform seriei IEC 60900. Se emit permise de lucru pentru lucr\u0103rile la \u00een\u0103l\u021bime \u0219i la cald. Electricienii de\u021bin autoriz\u0103rile necesare tipului de lucrare.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dirigen\u021bia de \u0219antier verific\u0103 conformitatea execu\u021biei cu proiectul. Dirigintele semneaz\u0103 procesele-verbale de recep\u021bie pe faze. Astfel beneficiarul are trasabilitate complet\u0103 pe toat\u0103 durata lucr\u0103rilor.<\/p>\n\n\n\n<h2 id=\"h-instala\u021bia-de-iluminat-arhitectural-\u0219i-func\u021bional\" class=\"wp-block-heading\">Instala\u021bia de iluminat arhitectural \u0219i func\u021bional<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Iluminatul unui birou trebuie s\u0103 sus\u021bin\u0103 concentrarea \u0219i confortul vizual. Lumina slab\u0103 obose\u0219te ochii. Lumina orbitoare scade productivitatea. Proiectul de iluminat porne\u0219te de la o simulare fotometric\u0103.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Simularea se realizeaz\u0103 \u00een software dedicat, precum DIALux evo sau Relux. Modelul 3D include geometria \u00eenc\u0103perilor \u0219i reflectan\u021bele suprafe\u021belor. Valorile uzuale sunt 0,7 pentru tavan, 0,5 pentru pere\u021bi \u0219i 0,2 pentru pardoseal\u0103. Factorul de mentenan\u021b\u0103 are, de obicei, valoarea 0,8. Calculul se face pe planul de lucru, la 0,75 m.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Echipa MHT Experience execut\u0103 solu\u021bia proiectat\u0103. Apoi o verific\u0103 prin m\u0103sur\u0103tori la recep\u021bie. Parametrii urm\u0103ri\u021bi sunt cei de mai jos:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Nivel de iluminare men\u021binut Em de 500 lx pe planul de lucru din birouri.<\/li>\n\n\n\n<li>Uniformitate U0 de minimum 0,6 pe zona activit\u0103\u021bii.<\/li>\n\n\n\n<li>Indice de redare a culorilor CRI peste 90 \u00een zonele de lucru premium.<\/li>\n\n\n\n<li>Indice de orbire UGR sub 19 \u00een birouri \u0219i s\u0103li de \u0219edin\u021be.<\/li>\n\n\n\n<li>Temperatur\u0103 de culoare \u00eentre 3000 K \u0219i 4000 K, cu toleran\u021b\u0103 de maximum 3 SDCM.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Standardul cere minimum Ra 80 \u00een birouri. \u021ainta CRI peste 90 cre\u0219te calitatea percep\u021biei culorilor. Tabelul de mai jos red\u0103 valorile minime de referin\u021b\u0103.<\/p>\n\n\n\n<pre class=\"wp-block-preformatted\">text<code>+-------------------------+---------+---------+--------+\n| Zon\u0103                    | Em (lx) | UGR max | Ra min |\n+-------------------------+---------+---------+--------+\n| Birouri, open-space     |   500   |   19    |   80   |\n| S\u0103li de \u0219edin\u021be         |   500   |   19    |   80   |\n| Recep\u021bie                |   300   |   22    |   80   |\n| Coridoare               |   100   |   28    |   40   |\n| Sc\u0103ri                   |   150   |   25    |   40   |\n| Camere tehnice          |   200   |   25    |   60   |\n+-------------------------+---------+---------+--------+\nSursa: SR EN 12464-1 (valori minime de referin\u021b\u0103)<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Driverele LED transform\u0103 o parte din energie \u00een c\u0103ldur\u0103. Un randament de 90\u201395% \u00eenseamn\u0103 pierderi de 5\u201310%. Aceste pierderi se acumuleaz\u0103 \u00een plenul tavanului fals. Temperatura ridicat\u0103 scurteaz\u0103 via\u021ba condensatoarelor electrolitice. Regula empiric\u0103 spune c\u0103 10 \u00b0C \u00een plus \u00eenjum\u0103t\u0103\u021besc durata de via\u021b\u0103.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Montajul respect\u0103 temperatura maxim\u0103 la punctul tc indicat de produc\u0103tor. Corpurile nu se acoper\u0103 cu izola\u021bii termice. Driverele au factor de putere peste 0,9 \u0219i flicker redus.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Driverele LED genereaz\u0103 curen\u021bi de pornire mari, de ordinul zecilor de amperi. Impulsul dureaz\u0103 sute de microsecunde. El poate declan\u0219a intempestiv un disjunctor subdimensionat. De aceea se limiteaz\u0103 num\u0103rul de corpuri pe circuit conform tabelelor produc\u0103torului. Curbele de declan\u0219are B sau C se aleg \u00een func\u021bie de acelea\u0219i tabele.<\/p>\n\n\n\n<h3 id=\"h-eficien\u021ba-energetica-\u0219i-protocoale-moderne-de-comanda\" class=\"wp-block-heading\">Eficien\u021b\u0103 energetic\u0103 \u0219i protocoale moderne de comand\u0103<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Comanda iluminatului folose\u0219te protocoale digitale deschise. DALI-2, definit \u00een seria IEC 62386, controleaz\u0103 corpurile printr-o magistral\u0103 cu dou\u0103 fire. O linie adreseaz\u0103 p\u00e2n\u0103 la 64 de dispozitive. Sistemul permite 16 grupuri \u0219i 16 scene. Magistrala nu are polaritate. C\u0103derea de tensiune pe magistral\u0103 r\u0103m\u00e2ne sub 2 V. Un cablu de 1,5 mm\u00b2 acoper\u0103 distan\u021be de p\u00e2n\u0103 la 300 m.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">KNX, standardizat prin ISO\/IEC 14543-3, integreaz\u0103 iluminatul cu jaluzelele \u0219i climatizarea. O interfa\u021b\u0103 KNX-DALI leag\u0103 cele dou\u0103 sisteme. Leg\u0103tura cu sistemul de management al cl\u0103dirii se face prin BACnet\/IP sau KNX IP.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Senzorii de prezen\u021b\u0103 sting lumina \u00een zonele goale. Senzorii de lumin\u0103 natural\u0103 men\u021bin nivelul \u021bint\u0103 prin reglaj constant. Programele orare adapteaz\u0103 iluminatul la orarul chiria\u0219ilor. \u00cen practic\u0103, reduceri de 30\u201350% ale consumului sunt uzuale. Indicatorul LENI din SR EN 15193-1 cuantific\u0103 performan\u021ba energetic\u0103 a iluminatului.<\/p>\n\n\n\n<h4 id=\"h-calibrarea-fluxului-luminos-conform-normativului-en-12464-1\" class=\"wp-block-heading\">Calibrarea fluxului luminos conform normativului EN 12464-1<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Punerea \u00een func\u021biune include adresarea DALI \u0219i calibrarea nivelurilor. Fluxul ini\u021bial se seteaz\u0103 la aproximativ 80% din maxim. Pe m\u0103sur\u0103 ce LED-urile \u00eemb\u0103tr\u00e2nesc, sistemul cre\u0219te treptat puterea. Astfel se compenseaz\u0103 deprecia\u021bia fluxului luminos. Consumul ini\u021bial scade, iar iluminarea r\u0103m\u00e2ne constant\u0103.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La recep\u021bie se m\u0103soar\u0103 iluminarea cu luxmetrul, pe o gril\u0103 de puncte. Valorile se compar\u0103 cu simularea. Abaterile se corecteaz\u0103 prin reglaj sau repozi\u021bionare. Rezultatele intr\u0103 \u00een dosarul de predare.<\/p>\n\n\n\n<h2 id=\"h-iluminat-de-siguran\u021ba-\u0219i-de-continuare-a-lucrului\" class=\"wp-block-heading\">Iluminat de siguran\u021b\u0103 \u0219i de continuare a lucrului<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Iluminatul de siguran\u021b\u0103 protejeaz\u0103 via\u021ba oamenilor la c\u0103derea aliment\u0103rii. SR EN 1838 define\u0219te cerin\u021bele fotometrice. NP-061 stabile\u0219te condi\u021biile de proiectare la nivel na\u021bional. Ambele norme separ\u0103 mai multe func\u021bii:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Iluminat pentru evacuare:<\/strong> marcheaz\u0103 \u0219i lumineaz\u0103 c\u0103ile de ie\u0219ire.<\/li>\n\n\n\n<li><strong>Iluminat antipanic\u0103:<\/strong> reduce panica \u00een spa\u021biile deschise mari.<\/li>\n\n\n\n<li><strong>Iluminat pentru zone cu risc ridicat:<\/strong> permite oprirea \u00een siguran\u021b\u0103 a activit\u0103\u021bilor periculoase.<\/li>\n\n\n\n<li><strong>Iluminat de continuare a lucrului:<\/strong> men\u021bine activitatea \u00een spa\u021bii critice, precum camerele tehnice.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u00cen birouri, continuarea lucrului se aplic\u0103 rar. Ea apare la camere de comand\u0103 sau spa\u021bii de server. Valorile principale din SR EN 1838 sunt urm\u0103toarele:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pe c\u0103ile de evacuare, iluminarea la pardoseal\u0103 este de minimum 1 lux pe axa central\u0103.<\/li>\n\n\n\n<li>Banda central\u0103, de 50% din l\u0103\u021bime, prime\u0219te minimum 0,5 lux.<\/li>\n\n\n\n<li>Raportul dintre valoarea maxim\u0103 \u0219i minim\u0103 pe ax\u0103 nu dep\u0103\u0219e\u0219te 40:1.<\/li>\n\n\n\n<li>Spa\u021biile deschise antipanic\u0103 primesc minimum 0,5 lux, f\u0103r\u0103 marginea de 0,5 m.<\/li>\n\n\n\n<li>Zonele cu risc ridicat primesc 10% din iluminarea normal\u0103, dar minimum 15 lux.<\/li>\n\n\n\n<li>Indicele de redare a culorilor este de minimum 40.<\/li>\n\n\n\n<li>Autonomia minim\u0103 este de o or\u0103.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Timpii de r\u0103spuns sunt la fel de importan\u021bi. Pe c\u0103ile de evacuare, corpurile ating 50% din nivel \u00een 5 secunde. Ele ating 100% \u00een 60 de secunde. Zonele cu risc ridicat cer 100% \u00een 0,5 secunde.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Solu\u021bia depinde de m\u0103rimea cl\u0103dirii \u0219i de politica de mentenan\u021b\u0103. Corpurile autonome simplific\u0103 cablarea. Bateria central\u0103 simplific\u0103 mentenan\u021ba. Tabelul de mai jos compar\u0103 cele dou\u0103 variante.<\/p>\n\n\n\n<pre class=\"wp-block-preformatted\">text<code>+---------------------+----------------------------+--------------------------------+\n| Criteriu            | Corpuri autonome           | Baterie central\u0103 (CPS)         |\n+---------------------+----------------------------+--------------------------------+\n| Sursa de energie    | Baterie \u00een fiecare corp    | Invertor + baterii dedicate    |\n| Cablare             | Circuit normal de iluminat | Circuite rezistente la foc     |\n| Mentenan\u021b\u0103          | Distribuit\u0103 pe multe puncte| Centralizat\u0103, \u00eentr-un loc      |\n| Investi\u021bie ini\u021bial\u0103 | Mai mic\u0103 la scar\u0103 redus\u0103   | Mai mare, amortizat\u0103 \u00een timp   |\n| Norm\u0103 de produs     | SR EN 60598-2-22           | SR EN 50171                    |\n+---------------------+----------------------------+--------------------------------+<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Sistemele centrale cer circuite cu rezisten\u021b\u0103 la foc, testate conform IEC 60331. Invertorul func\u021bioneaz\u0103 \u00een trei st\u0103ri: re\u021bea, urgen\u021b\u0103 \u0219i revenire. Comutarea rapid\u0103, sub 0,5 secunde, deserve\u0219te zonele cu risc ridicat.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Diagrama de mai jos prezint\u0103 logica de comutare.<\/p>\n\n\n\n<pre class=\"wp-block-preformatted\">text<code>REGIM NORMAL (re\u021bea prezent\u0103)\n------------------------------------------------------------------\nRe\u021bea SEN --&gt; TG --&gt; TD nivel --&gt; Corp de iluminat + modul urgen\u021b\u0103\n                        |\n                        +--&gt; Releu de supraveghere a tensiunii\n                                   |\n                                   v\n                    Tensiune &lt; 60% Un ? --NU--&gt; \u00cenc\u0103rcare baterie (float)\n                                   |\n                                  DA\n                                   v\nREGIM DE URGEN\u021a\u0102 (re\u021bea c\u0103zut\u0103)\n------------------------------------------------------------------\nComutare automat\u0103 --&gt; Invertor \/ baterie --&gt; Corp de siguran\u021b\u0103 aprins\n   |                                          (autonomie minim\u0103 1 h)\n   +--&gt; Zone cu risc ridicat : 100% E in &lt;= 0,5 s\n   +--&gt; C\u0103i de evacuare      :  50% E in &lt;= 5 s ; 100% E in &lt;= 60 s\n   +--&gt; Semnal de stare c\u0103tre panou de incendiu \/ BMS\n\nREVENIRE\n------------------------------------------------------------------\nTensiune &gt; prag --&gt; comutare pe re\u021bea --&gt; re\u00eenc\u0103rcare baterie<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Releul de supraveghere monitorizeaz\u0103 tensiunea de re\u021bea. Sub 60% din tensiunea nominal\u0103, corpurile autonome trec \u00een regim de urgen\u021b\u0103. Bateria preia sarcina f\u0103r\u0103 \u00eentrerupere vizibil\u0103. La revenirea re\u021belei, corpul comut\u0103 \u00eenapoi \u0219i re\u00eencarc\u0103 bateria.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Panoul de incendiu poate comanda aprinderea corpurilor din zonele afectate. Comanda se transmite printr-un contact liber de poten\u021bial.<\/p>\n\n\n\n<h3 id=\"h-tehnologii-de-protec\u021bie-a-cailor-de-evacuare-conform-en-1838\" class=\"wp-block-heading\">Tehnologii de protec\u021bie a c\u0103ilor de evacuare conform EN 1838<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Corpurile de siguran\u021b\u0103 respect\u0103 SR EN 60598-2-22. Se prefer\u0103 sursele LED cu baterii de durat\u0103 lung\u0103. Gradul de protec\u021bie se alege dup\u0103 mediu. Sc\u0103rile exterioare cer IP mai ridicat dec\u00e2t birourile.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">SR EN 1838 impune iluminarea punctelor critice. Fiecare ie\u0219ire prime\u0219te un corp propriu. Schimb\u0103rile de direc\u021bie \u0219i intersec\u021biile se ilumineaz\u0103 separat. Fiecare treapt\u0103 de scar\u0103 prime\u0219te lumin\u0103 direct\u0103. Echipamentele de stingere \u0219i punctele de prim ajutor au iluminare dedicat\u0103.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Semnalizatoarele de evacuare folosesc pictograme conform ISO 7010. Ele se amplaseaz\u0103 la ie\u0219iri \u0219i la fiecare schimbare de direc\u021bie. Calculul de urgen\u021b\u0103 ignor\u0103 lumina reflectat\u0103. Astfel rezultatul r\u0103m\u00e2ne sigur chiar \u00een cele mai defavorabile condi\u021bii.<\/p>\n\n\n\n<h4 id=\"h-testarea-automata-a-lampilor-de-evacuare-\u0219i-diagnoza\" class=\"wp-block-heading\">Testarea automat\u0103 a l\u0103mpilor de evacuare \u0219i diagnoz\u0103<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Testarea manual\u0103 a sute de corpuri consum\u0103 timp \u0219i genereaz\u0103 erori. Sistemele automate urmeaz\u0103 SR EN 62034. Comunicarea folose\u0219te DALI conform IEC 62386-202 sau un protocol al produc\u0103torului.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">SR EN 50172 recomand\u0103 un ciclu de verific\u0103ri:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Verificare zilnic\u0103 a indicatoarelor de stare.<\/li>\n\n\n\n<li>Test func\u021bional lunar, de scurt\u0103 durat\u0103.<\/li>\n\n\n\n<li>Test anual de autonomie complet\u0103.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Testele se e\u0219aloneaz\u0103 pe grupuri de corpuri. Astfel nu se descarc\u0103 toate bateriile simultan. Sistemul clasific\u0103 defectele: baterie, surs\u0103 LED, \u00eenc\u0103rc\u0103tor sau comunica\u021bie. Rapoartele se arhiveaz\u0103 \u00een registrul de mentenan\u021b\u0103. Auditorii pot verifica oric\u00e2nd istoricul testelor.<\/p>\n\n\n\n<h2 id=\"h-racorduri-de-for\u021ba-tablouri-de-distribu\u021bie-\u0219i-re\u021bea-de-prize\" class=\"wp-block-heading\">Racorduri de for\u021b\u0103, tablouri de distribu\u021bie \u0219i re\u021bea de prize<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Instala\u021biile de for\u021b\u0103 alimenteaz\u0103 toate func\u021biile cl\u0103dirii. Ele respect\u0103 SR HD 60364 \u0219i IEC 60364. Arhitectura este ierarhic\u0103. Tabloul general alimenteaz\u0103 tablourile de distribu\u021bie. Acestea alimenteaz\u0103 circuitele terminale.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tablourile de subdistribu\u021bie se amplaseaz\u0103 pe nivel sau pe zon\u0103. Ele grupeaz\u0103 circuitele pe func\u021biuni:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Iluminatul normal are circuite proprii.<\/li>\n\n\n\n<li>Prizele de uz general au circuite proprii.<\/li>\n\n\n\n<li>Prizele IT au circuite dedicate de energie curat\u0103.<\/li>\n\n\n\n<li>Circuitele de siguran\u021b\u0103 sunt separate \u0219i rezistente la foc.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ansamblurile respect\u0103 seria IEC 61439. Se prevede o rezerv\u0103 de 20\u201330% pentru extinderi. Sarcinile se echilibreaz\u0103 \u00eentre faze. Dezechilibrul r\u0103m\u00e2ne sub 10\u201315%.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sursele \u00een comuta\u021bie genereaz\u0103 armonica a treia. Aceasta se \u00eensumeaz\u0103 pe conductorul neutru. \u00cen cazuri extreme, curentul din neutru dep\u0103\u0219e\u0219te curentul de faz\u0103. Pe circuitele IT dense, neutrul are sec\u021biune egal\u0103 cu faza sau mai mare. Regulile se reg\u0103sesc \u00een SR HD 60364-5-52.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Circuitele IT de energie curat\u0103 sunt separate de motoare \u0219i climatizare. Ele au protec\u021bie diferen\u021bial\u0103 proprie. Schema de legare la p\u0103m\u00e2nt este TN-S \u00een aval de punctul de separare. Conductorul PEN nu se folose\u0219te \u00een aval. Legarea echipoten\u021bial\u0103 urmeaz\u0103 EN 50310. Fiecare rack prime\u0219te circuite dedicate \u0219i SPD de tip 3 \u00een apropiere.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Protec\u021bia la supratensiuni se face \u00een trepte coordonate:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>SPD de tip 1 sau 1+2 se monteaz\u0103 la tabloul general, dac\u0103 exist\u0103 risc de tr\u0103snet direct.<\/li>\n\n\n\n<li>SPD de tip 2 se monteaz\u0103 \u00een tablourile de distribu\u021bie.<\/li>\n\n\n\n<li>SPD de tip 3 protejeaz\u0103 echipamentele sensibile, aproape de sarcin\u0103.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dispozitivele respect\u0103 SR EN 61643-11. Nivelul de protec\u021bie Up al tipului 2 este de obicei sub 1,5 kV. \u00centre trepte se respect\u0103 distan\u021ba de decuplare indicat\u0103 de produc\u0103tor. Conductoarele de legare la p\u0103m\u00e2nt ale SPD r\u0103m\u00e2n c\u00e2t mai scurte.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cablurile LSZH, cu emisii reduse de fum \u0219i f\u0103r\u0103 halogeni, limiteaz\u0103 pericolul \u00een caz de incendiu. Ele respect\u0103 IEC 60754 pentru gaze acide. Ele respect\u0103 IEC 61034 pentru densitatea fumului. Circuitele de siguran\u021b\u0103 folosesc cabluri rezistente la foc, testate conform IEC 60331, de tip E30 sau E90. Sus\u021binerile \u00ee\u0219i men\u021bin integritatea la foc. Trecerile prin pere\u021bi se etan\u0219eaz\u0103 antifoc.<\/p>\n\n\n\n<h3 id=\"h-modificari-\u0219i-completari-la-tablourile-existente\" class=\"wp-block-heading\">Modific\u0103ri \u0219i complet\u0103ri la tablourile existente<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Modific\u0103rile la tablouri se fac adesea \u00een cl\u0103diri \u00een func\u021biune. MHT Experience \u00eencepe cu un audit al tabloului. Se verific\u0103 barele colectoare, aparatajul \u0219i str\u00e2ngerea bornelor. Termografia \u00een infraro\u0219u identific\u0103 punctele calde. Schema monofilar\u0103 se actualizeaz\u0103.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Complet\u0103rile respect\u0103 instruc\u021biunile produc\u0103torului tabloului. Se recalculeaz\u0103 curentul de scurtcircuit \u0219i capacitatea barelor. \u00centreruperile se planific\u0103 \u00een ferestre scurte, aprobate de beneficiar. Etichetarea circuitelor se actualizeaz\u0103 la final.<\/p>\n\n\n\n<h4 id=\"h-verificarea-conform-iec-61439-\u0219i-hd-60364-6\" class=\"wp-block-heading\">Verificarea conform IEC 61439 \u0219i HD 60364-6<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Orice modificare se verific\u0103 pe baza seriei IEC 61439. Se verific\u0103 \u00eenc\u0103lzirea, rezisten\u021ba la scurtcircuit \u0219i distan\u021bele de izolare. Dup\u0103 interven\u021bie se execut\u0103 m\u0103sur\u0103tori individuale:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Rezisten\u021ba de izola\u021bie se m\u0103soar\u0103 cu 500 V c.c. Valoarea minim\u0103 este de 1 M\u03a9.<\/li>\n\n\n\n<li>Se verific\u0103 ordinea fazelor.<\/li>\n\n\n\n<li>Se verific\u0103 continuitatea conductoarelor PE.<\/li>\n\n\n\n<li>Se testeaz\u0103 declan\u0219area RCD la I\u0394n \u0219i la 5 \u00d7 I\u0394n.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Rezultatele se consemneaz\u0103 \u00een buletine de m\u0103surare. Buletinele intr\u0103 \u00een dosarul de predare.<\/p>\n\n\n\n<h3 id=\"h-dimensionarea-circuitelor-electrice-terminale\" class=\"wp-block-heading\">Dimensionarea circuitelor electrice terminale<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Dimensionarea urmeaz\u0103 o secven\u021b\u0103 fix\u0103. Se stabile\u0219te curentul de proiect Ib. Se alege curentul nominal In al protec\u021biei. Se verific\u0103 capacitatea de transport Iz a cablului, cu factori de corec\u021bie. Se calculeaz\u0103 c\u0103derea de tensiune. Se verific\u0103 timpul de deconectare la defect. Se verific\u0103 rezisten\u021ba conductorului la scurtcircuit.<\/p>\n\n\n\n<pre class=\"wp-block-preformatted\">text<code>Ib &lt;= In &lt;= Iz\nI2 &lt;= 1,45 x Iz\nZs x Ia &lt;= U0\nk^2 x S^2 &gt;= I^2 x t<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Legenda m\u0103rimilor:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Ib: curentul de proiect al circuitului.<\/li>\n\n\n\n<li>In: curentul nominal al dispozitivului de protec\u021bie.<\/li>\n\n\n\n<li>Iz: curentul admisibil al cablului.<\/li>\n\n\n\n<li>I2: curentul conven\u021bional de declan\u0219are.<\/li>\n\n\n\n<li>Zs: impedan\u021ba buclei de defect.<\/li>\n\n\n\n<li>Ia: curentul care asigur\u0103 declan\u0219area \u00een timpul impus.<\/li>\n\n\n\n<li>U0: tensiunea nominal\u0103 fa\u021b\u0103 de p\u0103m\u00e2nt.<\/li>\n\n\n\n<li>k: factorul de material \u0219i izola\u021bie al conductorului.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Exemplu de calcul: un circuit alimenteaz\u0103 12 corpuri LED de 40 W. Puterea total\u0103 este de 480 W. Cu factor de putere 0,95, curentul Ib este de aproximativ 2,2 A. Un cablu de 1,5 mm\u00b2 cu protec\u021bie de 10 A acoper\u0103 sarcina. Limita real\u0103 r\u0103m\u00e2ne curentul de pornire al driverelor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00cen schema TN, circuitele terminale p\u00e2n\u0103 la 32 A se deconecteaz\u0103 \u00een maximum 0,4 s la 230 V. Circuitele de distribu\u021bie admit maximum 5 s. Limita de proiectare uzual\u0103 pentru c\u0103derea de tensiune este de 4%, de la origine la sarcin\u0103.<\/p>\n\n\n\n<h4 id=\"h-protec\u021bie-diferen\u021biala-\u0219i-selectivitatea-declan\u0219arii\" class=\"wp-block-heading\">Protec\u021bie diferen\u021bial\u0103 \u0219i selectivitatea declan\u0219\u0103rii<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Selectivitatea limiteaz\u0103 \u00eentreruperea la circuitul afectat. Un defect pe o priz\u0103 nu trebuie s\u0103 opreasc\u0103 un nivel \u00eentreg. IEC 60947-2 define\u0219te cerin\u021bele pentru \u00eentrerup\u0103toarele automate industriale. Produc\u0103torii public\u0103 tabele de selectivitate pentru combina\u021biile de aparate.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Exist\u0103 trei tipuri de selectivitate: amperometric\u0103, cronometric\u0103 \u0219i energetic\u0103. Filia\u021bia, adic\u0103 protec\u021bia de rezerv\u0103, este o solu\u021bie diferit\u0103. Ea limiteaz\u0103 selectivitatea total\u0103. Amonte se folosesc declan\u0219atoare electronice cu func\u021bii LSI. Ele permit temporizarea la scurtcircuit. Aval se folosesc disjunctoare modulare cu limitare a energiei.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Protec\u021bia diferen\u021bial\u0103 se etajeaz\u0103:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Amonte se monteaz\u0103 RCD de tip S, temporizat, de 300 mA.<\/li>\n\n\n\n<li>Aval se monteaz\u0103 RCD instantaneu de 30 mA.<\/li>\n\n\n\n<li>Raportul dintre curen\u021bii nominali este de minimum 3.<\/li>\n\n\n\n<li>Circuitele de prize p\u00e2n\u0103 la 32 A au RCD de 30 mA, conform SR HD 60364-4-41.<\/li>\n\n\n\n<li>Circuitele IT folosesc RCD de tip A sau F. Redresoarele trifazate pot cere tip B.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Curentul de fug\u0103 cumulat al filtrelor EMC r\u0103m\u00e2ne sub 30% din I\u0394n. Astfel se evit\u0103 declan\u0219\u0103rile intempestive.<\/p>\n\n\n\n<pre class=\"wp-block-preformatted\">text<code>TG (ACB\/MCCB, LSI)  ---&gt;  TD nivel (MCCB)  ---&gt;  Circuit terminal\nIn = 400 A                In = 100 A              MCB C16 + RCD 30 mA\nTsd = 0,3 s               Tsd = 0,1 s             declan\u0219are instantanee\n                          RCD-S 300 mA\n\nDefect pe circuitul terminal --&gt; declan\u0219eaz\u0103 doar MCB \/ RCD 30 mA\nTD \u0219i TG r\u0103m\u00e2n alimentate.\n(Schem\u0103 de principiu. Valorile reale rezult\u0103 din tabelele de selectivitate.)<\/code><\/pre>\n\n\n\n<h2 id=\"h-curen\u021bi-slabi-\u0219i-instala\u021bii-electrice-mindspace-victoriei-sisteme-integrate\" class=\"wp-block-heading\">Curen\u021bi slabi \u0219i instala\u021bii electrice Mindspace Victoriei: sisteme integrate<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Sistemele de curen\u021bi slabi func\u021bioneaz\u0103 ca un ecosistem. Datele, accesul, alarma \u0219i imaginea folosesc acelea\u0219i trasee \u0219i aceea\u0219i energie. MHT Experience le-a executat coordonat cu instala\u021biile de for\u021b\u0103. Astfel a evitat conflictele \u00eentre sisteme.<\/p>\n\n\n\n<h3 id=\"h-cablare-structurata-pentru-re\u021bele-de-date\" class=\"wp-block-heading\">Cablare structurat\u0103 pentru re\u021bele de date<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Cablarea structurat\u0103 urmeaz\u0103 seria SR EN 50173. Instalarea urmeaz\u0103 SR EN 50174. ISO\/IEC 11801 define\u0219te clasele de performan\u021b\u0103. Solu\u021bia de referin\u021b\u0103 pentru birouri folose\u0219te cabluri de cupru din categoria 6A. Ele sus\u021bin 10GBASE-T pe 100 m. Din canalul de 100 m, leg\u0103tura permanent\u0103 are cel mult 90 m. Coloanele verticale folosesc fibr\u0103 optic\u0103 OM4 sau OS2.<\/p>\n\n\n\n<pre class=\"wp-block-preformatted\">text<code>[Punct de lucru RJ45] --Cat. 6A, max 90 m--&gt; [Patch panel etaj]\n                                                   |\n                                            [Switch acces PoE]\n                                                   |\n                                   fibr\u0103 OM4 \/ OS2 (coloan\u0103 vertical\u0103)\n                                                   |\n                                     [Sal\u0103 tehnic\u0103 \/ rack principal]<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">PoE conform IEEE 802.3bt alimenteaz\u0103 camere, puncte de acces \u0219i cititoare. Puterea de p\u00e2n\u0103 la 90 W \u00eenc\u0103lze\u0219te fasciculele de cabluri. De aceea se limiteaz\u0103 num\u0103rul de cabluri pe fascicul.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Separarea fa\u021b\u0103 de cablurile de for\u021b\u0103 urmeaz\u0103 SR EN 50174-2. Rack-urile se leag\u0103 la bara de echipoten\u021bializare. Fiecare punct prime\u0219te o etichet\u0103 unic\u0103. La final, fiecare leg\u0103tur\u0103 se certific\u0103 cu un tester de clas\u0103 EA. Rapoartele se predau \u00een format electronic.<\/p>\n\n\n\n<h3 id=\"h-control-acces-\u0219i-integrarea-cu-evacuarea\" class=\"wp-block-heading\">Control acces \u0219i integrarea cu evacuarea<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Controlul accesului stabile\u0219te cine intr\u0103, unde \u0219i c\u00e2nd. Controlerele iau decizia local. Astfel u\u0219ile func\u021bioneaz\u0103 chiar dac\u0103 serverul cade. Sistemele electronice de control acces se raporteaz\u0103 la SR EN 60839-11-1.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cititoarele moderne folosesc protocolul OSDP v2 cu canal securizat. Wiegand este dep\u0103\u0219it \u0219i vulnerabil la interceptare. Cardurile folosesc criptare AES, de exemplu MIFARE DESFire. Sursele au acumulator pentru func\u021bionarea la lipsa re\u021belei.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pe c\u0103ile de evacuare, broa\u0219tele se aleg \u00een varianta fail-safe. Panoul de incendiu deblocheaz\u0103 automat u\u0219ile de pe aceste trasee. Feroneria de evacuare respect\u0103 SR EN 179 \u0219i SR EN 1125. Datele personale se prelucreaz\u0103 conform GDPR, adic\u0103 Regulamentului UE 2016\/679.<\/p>\n\n\n\n<h3 id=\"h-detec\u021bie-incendiu-conform-en-54-\u0219i-p118-3\" class=\"wp-block-heading\">Detec\u021bie incendiu conform EN 54 \u0219i P118\/3<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Sistemul de detec\u021bie este adresabil, pe bucl\u0103. Componentele respect\u0103 seria SR EN 54. Centrala respect\u0103 EN 54-2, iar sursa de alimentare EN 54-4. Detectoarele de fum respect\u0103 EN 54-7. Butoanele manuale respect\u0103 EN 54-11. Sirenele respect\u0103 EN 54-3. Proiectarea \u0219i montajul urmeaz\u0103 normativul P118\/3 \u0219i CEN\/TS 54-14.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">MHT Experience de\u021bine autorizarea IGSU pentru detec\u021bie, semnalizare de alarm\u0103 \u0219i sisteme de siguran\u021b\u0103 a vie\u021bii. Bucla se calculeaz\u0103 pentru rezisten\u021b\u0103, capacitate \u0219i curent. Izolatoarele de scurtcircuit limiteaz\u0103 efectul unei avarii. Cablurile sunt ecranate \u0219i rezistente la foc. De regul\u0103, bateriile asigur\u0103 24 de ore de veghe \u0219i 30 de minute de alarm\u0103.<\/p>\n\n\n\n<h4 id=\"h-punerea-in-func\u021biune-\u0219i-matricea-cauza-efect\" class=\"wp-block-heading\">Punerea \u00een func\u021biune \u0219i matricea cauz\u0103-efect<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Matricea cauz\u0103-efect leag\u0103 fiecare alarm\u0103 de ac\u021biunile automate. O alarm\u0103 poate opri ventila\u021bia \u0219i chema liftul la parter. Ea poate debloca u\u0219ile \u0219i porni iluminatul de siguran\u021b\u0103. Fiecare scenariu se testeaz\u0103 la punerea \u00een func\u021biune. Fiecare detector se testeaz\u0103 individual, cu aerosol sau cu surs\u0103 de fum. Rezultatele se consemneaz\u0103 \u00eentr-un raport.<\/p>\n\n\n\n<h3 id=\"h-supraveghere-video-\u0219i-protec\u021bia-datelor\" class=\"wp-block-heading\">Supraveghere video \u0219i protec\u021bia datelor<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Supravegherea video folose\u0219te camere IP alimentate prin PoE. Proiectarea urm\u0103re\u0219te SR EN 62676-4. Standardul define\u0219te nivelurile de identificare prin densitatea de pixeli:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Detectarea cere 25 px\/m.<\/li>\n\n\n\n<li>Observarea cere 62,5 px\/m.<\/li>\n\n\n\n<li>Recunoa\u0219terea cere 125 px\/m.<\/li>\n\n\n\n<li>Identificarea cere 250 px\/m.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Compresia H.265 reduce banda \u0219i spa\u021biul de stocare. Pozi\u021bionarea camerelor \u021bine cont de contralumin\u0103 \u0219i de unghiul de vizualizare.<\/p>\n\n\n\n<h4 id=\"h-dimensionarea-stocarii-\u0219i-securitatea-cibernetica\" class=\"wp-block-heading\">Dimensionarea stoc\u0103rii \u0219i securitatea cibernetic\u0103<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Stocarea se calculeaz\u0103 din rata de bi\u021bi, num\u0103rul de camere \u0219i zilele de reten\u021bie. Exemplu de calcul: 20 de camere la 4 Mbps consum\u0103 aproximativ 864 GB pe zi. Pentru 30 de zile rezult\u0103 circa 26 TB, \u00eenainte de redundan\u021ba RAID.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Re\u021beaua video se izoleaz\u0103 \u00eentr-un VLAN dedicat. Se folosesc autentificare 802.1X \u0219i HTTPS. Parolele implicite se elimin\u0103. Firmware-ul se actualizeaz\u0103 controlat. Accesul urmeaz\u0103 principiul privilegiului minim. Aceste practici se aliniaz\u0103 cu ISO 27001. Imaginile se prelucreaz\u0103 conform GDPR, cu informare prin panouri vizibile.<\/p>\n\n\n\n<h2 id=\"h-de-ce-aleg-marii-beneficiari-expertiza-mht-experience\" class=\"wp-block-heading\">De ce aleg marii beneficiari expertiza MHT Experience<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Instala\u021bii electrice Mindspace Victoriei arat\u0103 o metod\u0103 de lucru repetabil\u0103. Beneficiarii mari caut\u0103 predictibilitate, nu improviza\u021bie. Iat\u0103 ce primesc de la MHT Experience:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Zero dep\u0103\u0219iri de buget.<\/strong> Nu ad\u0103ug\u0103m costuri dac\u0103 parametrii tehnici ini\u021biali r\u0103m\u00e2n neschimba\u021bi. Pre\u021bul convenit este pre\u021bul final.<\/li>\n\n\n\n<li><strong>Predictibilitate opera\u021bional\u0103.<\/strong> Filosofia \u201eMaking a habit of trust&#8221; \u00eenseamn\u0103 termene clare \u0219i raportare constant\u0103. Ea \u00eenseamn\u0103 un parteneriat f\u0103r\u0103 surprize.<\/li>\n\n\n\n<li><strong>Livrare la termen.<\/strong> Planificarea pe faze \u0219i un singur executant elimin\u0103 timpii mor\u021bi.<\/li>\n\n\n\n<li><strong>Autoriz\u0103ri ANRE.<\/strong> De\u021binem atestate de tip D2, E2 \u0219i C1B pentru joas\u0103 \u0219i medie tensiune.<\/li>\n\n\n\n<li><strong>Autorizare IGSU.<\/strong> Suntem certifica\u021bi pentru detec\u021bie incendiu, semnalizare de alarm\u0103 \u0219i sisteme de siguran\u021b\u0103 a vie\u021bii.<\/li>\n\n\n\n<li><strong>ISO 45001.<\/strong> Sistemul de s\u0103n\u0103tate \u0219i securitate ocupa\u021bional\u0103 protejeaz\u0103 oamenii de pe \u0219antier.<\/li>\n\n\n\n<li><strong>ISO 27001.<\/strong> Securitatea informa\u021biei protejeaz\u0103 datele clientului. Aceasta conteaz\u0103 la control acces \u0219i supraveghere video.<\/li>\n\n\n\n<li><strong>ISO 37001.<\/strong> Politica anti-mit\u0103 garanteaz\u0103 transparen\u021b\u0103 \u00een rela\u021biile comerciale.<\/li>\n\n\n\n<li><strong>Peste 10 ani de experien\u021b\u0103.<\/strong> Am livrat proiecte comerciale, retail, reziden\u021biale \u0219i facilit\u0103\u021bi critice.<\/li>\n\n\n\n<li><strong>Documenta\u021bie complet\u0103.<\/strong> Pred\u0103m scheme as-built, buletine de m\u0103surare \u0219i rapoarte de testare.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ai un proiect de birouri, retail sau spa\u021bii comerciale? Contacteaz\u0103 echipa MHT Experience pentru o evaluare tehnic\u0103. Prime\u0219ti o ofert\u0103 clar\u0103, cu parametri tehnici defini\u021bi.<\/p>\n\n\n\n<h3 id=\"h-resurse-externe\" class=\"wp-block-heading\">Resurse externe<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.iec.ch\/\" target=\"_blank\" rel=\"noopener\">IEC \u2013 International Electrotechnical Commission<\/a> &#8211; Organismul care public\u0103 seriile IEC 60364 \u0219i IEC 60947. Ele definesc instala\u021biile de joas\u0103 tensiune \u0219i aparatajul de protec\u021bie.<\/li>\n\n\n\n<li><a href=\"https:\/\/www.cibse.org\/\" target=\"_blank\" rel=\"noopener\">CIBSE \u2013 Chartered Institution of Building Services Engineers<\/a> &#8211; Ghiduri de referin\u021b\u0103 pentru iluminat, iluminat de siguran\u021b\u0103 \u0219i servicii tehnice \u00een cl\u0103diri.<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>Instala\u021bii electrice Mindspace Victoriei TCI Tower: execu\u021bie integrat\u0103 Cl\u0103dirile de birouri moderne nu tolereaz\u0103 erorile de execu\u021bie. Chiria\u0219ii cer confort vizual, re\u021bea stabil\u0103 \u0219i siguran\u021b\u0103 la incendiu. Toate acestea pornesc de la o instala\u021bie bine executat\u0103. Proiectul Mindspace Victoriei TCI Tower a reunit aceste cerin\u021be. MHT Experience a executat instala\u021bii electrice Mindspace Victoriei \u0219i sistemele [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3242,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jet_sm_ready_style":"","_jet_sm_style":"","_jet_sm_controls_values":"","_jet_sm_fonts_collection":"","_jet_sm_fonts_links":"","footnotes":""},"categories":[7,6],"tags":[149,170,151,156,277,35,199,45,200],"class_list":["post-3239","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-birouri","category-portofoliu","tag-cablare-structurata-2","tag-control-acces","tag-detectie-incendiu-2","tag-iluminat-de-siguranta","tag-iluminat-led-dali-2","tag-instalatii-electrice","tag-sr-hd-60364","tag-supraveghere-video","tag-tablouri-electrice"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.2 (Yoast SEO v28.6) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Instala\u021bii electrice Mindspace Victoriei | MHT Experience<\/title>\n<meta name=\"description\" content=\"Instala\u021bii electrice Mindspace Victoriei: MHT Experience a executat for\u021b\u0103, iluminat, curen\u021bi slabi \u0219i detec\u021bie incendiu \u00een TCI Tower.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/mht-experience.ro\/en\/mindspace-victoriei-tci-tower\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Mindspace Victoriei TCI Tower\" \/>\n<meta property=\"og:description\" content=\"Instala\u021bii electrice Mindspace Victoriei: MHT Experience a executat for\u021b\u0103, iluminat, curen\u021bi slabi \u0219i detec\u021bie incendiu \u00een TCI Tower.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/mht-experience.ro\/en\/mindspace-victoriei-tci-tower\/\" \/>\n<meta property=\"og:site_name\" content=\"MHT Experience\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/MHTexperience\/\" \/>\n<meta property=\"article:published_time\" content=\"2019-05-27T09:36:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-29T06:10:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/mht-experience.ro\/wp-content\/uploads\/2022\/04\/mindspace_victoriei_tci_tower_01.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1400\" \/>\n\t<meta property=\"og:image:height\" content=\"590\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Muug Design\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Muug Design\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"19 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/mindspace-victoriei-tci-tower\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/mindspace-victoriei-tci-tower\\\/\"},\"author\":{\"name\":\"Muug Design\",\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/#\\\/schema\\\/person\\\/078400ee203d5f5a5bfb135a8d126e59\"},\"headline\":\"Mindspace Victoriei TCI Tower\",\"datePublished\":\"2019-05-27T09:36:00+00:00\",\"dateModified\":\"2026-09-29T06:10:48+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/mindspace-victoriei-tci-tower\\\/\"},\"wordCount\":3602,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/mindspace-victoriei-tci-tower\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/mht-experience.ro\\\/wp-content\\\/uploads\\\/2022\\\/04\\\/mindspace_victoriei_tci_tower_01.webp\",\"keywords\":[\"Cablare Structurat\u0103\",\"Control Acces\",\"Detec\u021bie Incendiu\",\"Iluminat De Siguran\u021b\u0103\",\"iluminat LED DALI-2\",\"Instala\u021bii electrice\",\"SR HD 60364\",\"supraveghere video\",\"tablouri electrice\"],\"articleSection\":[\"Birouri\",\"Portofoliu\"],\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/mht-experience.ro\\\/mindspace-victoriei-tci-tower\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/mindspace-victoriei-tci-tower\\\/\",\"url\":\"https:\\\/\\\/mht-experience.ro\\\/mindspace-victoriei-tci-tower\\\/\",\"name\":\"Instala\u021bii electrice Mindspace Victoriei | MHT Experience\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/mindspace-victoriei-tci-tower\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/mindspace-victoriei-tci-tower\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/mht-experience.ro\\\/wp-content\\\/uploads\\\/2022\\\/04\\\/mindspace_victoriei_tci_tower_01.webp\",\"datePublished\":\"2019-05-27T09:36:00+00:00\",\"dateModified\":\"2026-09-29T06:10:48+00:00\",\"description\":\"Instala\u021bii electrice Mindspace Victoriei: MHT Experience a executat for\u021b\u0103, iluminat, curen\u021bi slabi \u0219i detec\u021bie incendiu \u00een TCI Tower.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/mindspace-victoriei-tci-tower\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/mht-experience.ro\\\/mindspace-victoriei-tci-tower\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/mindspace-victoriei-tci-tower\\\/#primaryimage\",\"url\":\"https:\\\/\\\/mht-experience.ro\\\/wp-content\\\/uploads\\\/2022\\\/04\\\/mindspace_victoriei_tci_tower_01.webp\",\"contentUrl\":\"https:\\\/\\\/mht-experience.ro\\\/wp-content\\\/uploads\\\/2022\\\/04\\\/mindspace_victoriei_tci_tower_01.webp\",\"width\":1400,\"height\":590,\"caption\":\"Instala\u021bii electrice Mindspace Victoriei | MHT Experience\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/mindspace-victoriei-tci-tower\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Prima pagin\u0103\",\"item\":\"https:\\\/\\\/mht-experience.ro\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Mindspace Victoriei TCI Tower\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/#website\",\"url\":\"https:\\\/\\\/mht-experience.ro\\\/\",\"name\":\"MHT Experience\",\"description\":\"Instala\u021bii Electrice\",\"publisher\":{\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/mht-experience.ro\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/#organization\",\"name\":\"MHT Experience\",\"url\":\"https:\\\/\\\/mht-experience.ro\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/mht-experience.ro\\\/wp-content\\\/uploads\\\/2022\\\/02\\\/mht-experience-simple-blue.svg\",\"contentUrl\":\"https:\\\/\\\/mht-experience.ro\\\/wp-content\\\/uploads\\\/2022\\\/02\\\/mht-experience-simple-blue.svg\",\"width\":512,\"height\":154,\"caption\":\"MHT Experience\"},\"image\":{\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/MHTexperience\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/sc-mht-experience-srl-d\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/mht-experience.ro\\\/#\\\/schema\\\/person\\\/078400ee203d5f5a5bfb135a8d126e59\",\"name\":\"Muug Design\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/639a82f2d6018b07ddb3bbd331072f4c30087d1abc554894590a04495eb8283c?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/639a82f2d6018b07ddb3bbd331072f4c30087d1abc554894590a04495eb8283c?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/639a82f2d6018b07ddb3bbd331072f4c30087d1abc554894590a04495eb8283c?s=96&d=mm&r=g\",\"caption\":\"Muug Design\"},\"sameAs\":[\"https:\\\/\\\/mht-experience.ro\"],\"url\":\"https:\\\/\\\/mht-experience.ro\\\/en\\\/author\\\/george-tone\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Instala\u021bii electrice Mindspace Victoriei | MHT Experience","description":"Instala\u021bii electrice Mindspace Victoriei: MHT Experience a executat for\u021b\u0103, iluminat, curen\u021bi slabi \u0219i detec\u021bie incendiu \u00een TCI Tower.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/mht-experience.ro\/en\/mindspace-victoriei-tci-tower\/","og_locale":"en_GB","og_type":"article","og_title":"Mindspace Victoriei TCI Tower","og_description":"Instala\u021bii electrice Mindspace Victoriei: MHT Experience a executat for\u021b\u0103, iluminat, curen\u021bi slabi \u0219i detec\u021bie incendiu \u00een TCI Tower.","og_url":"https:\/\/mht-experience.ro\/en\/mindspace-victoriei-tci-tower\/","og_site_name":"MHT Experience","article_publisher":"https:\/\/www.facebook.com\/MHTexperience\/","article_published_time":"2019-05-27T09:36:00+00:00","article_modified_time":"2026-09-29T06:10:48+00:00","og_image":[{"width":1400,"height":590,"url":"https:\/\/mht-experience.ro\/wp-content\/uploads\/2022\/04\/mindspace_victoriei_tci_tower_01.webp","type":"image\/webp"}],"author":"Muug Design","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Muug Design","Estimated reading time":"19 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/mht-experience.ro\/mindspace-victoriei-tci-tower\/#article","isPartOf":{"@id":"https:\/\/mht-experience.ro\/mindspace-victoriei-tci-tower\/"},"author":{"name":"Muug Design","@id":"https:\/\/mht-experience.ro\/#\/schema\/person\/078400ee203d5f5a5bfb135a8d126e59"},"headline":"Mindspace Victoriei TCI Tower","datePublished":"2019-05-27T09:36:00+00:00","dateModified":"2026-09-29T06:10:48+00:00","mainEntityOfPage":{"@id":"https:\/\/mht-experience.ro\/mindspace-victoriei-tci-tower\/"},"wordCount":3602,"commentCount":0,"publisher":{"@id":"https:\/\/mht-experience.ro\/#organization"},"image":{"@id":"https:\/\/mht-experience.ro\/mindspace-victoriei-tci-tower\/#primaryimage"},"thumbnailUrl":"https:\/\/mht-experience.ro\/wp-content\/uploads\/2022\/04\/mindspace_victoriei_tci_tower_01.webp","keywords":["Cablare Structurat\u0103","Control Acces","Detec\u021bie Incendiu","Iluminat De Siguran\u021b\u0103","iluminat LED DALI-2","Instala\u021bii electrice","SR HD 60364","supraveghere video","tablouri electrice"],"articleSection":["Birouri","Portofoliu"],"inLanguage":"en-GB","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/mht-experience.ro\/mindspace-victoriei-tci-tower\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/mht-experience.ro\/mindspace-victoriei-tci-tower\/","url":"https:\/\/mht-experience.ro\/mindspace-victoriei-tci-tower\/","name":"Instala\u021bii electrice Mindspace Victoriei | MHT Experience","isPartOf":{"@id":"https:\/\/mht-experience.ro\/#website"},"primaryImageOfPage":{"@id":"https:\/\/mht-experience.ro\/mindspace-victoriei-tci-tower\/#primaryimage"},"image":{"@id":"https:\/\/mht-experience.ro\/mindspace-victoriei-tci-tower\/#primaryimage"},"thumbnailUrl":"https:\/\/mht-experience.ro\/wp-content\/uploads\/2022\/04\/mindspace_victoriei_tci_tower_01.webp","datePublished":"2019-05-27T09:36:00+00:00","dateModified":"2026-09-29T06:10:48+00:00","description":"Instala\u021bii electrice Mindspace Victoriei: MHT Experience a executat for\u021b\u0103, iluminat, curen\u021bi slabi \u0219i detec\u021bie incendiu \u00een TCI Tower.","breadcrumb":{"@id":"https:\/\/mht-experience.ro\/mindspace-victoriei-tci-tower\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/mht-experience.ro\/mindspace-victoriei-tci-tower\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/mht-experience.ro\/mindspace-victoriei-tci-tower\/#primaryimage","url":"https:\/\/mht-experience.ro\/wp-content\/uploads\/2022\/04\/mindspace_victoriei_tci_tower_01.webp","contentUrl":"https:\/\/mht-experience.ro\/wp-content\/uploads\/2022\/04\/mindspace_victoriei_tci_tower_01.webp","width":1400,"height":590,"caption":"Instala\u021bii electrice Mindspace Victoriei | MHT Experience"},{"@type":"BreadcrumbList","@id":"https:\/\/mht-experience.ro\/mindspace-victoriei-tci-tower\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Prima pagin\u0103","item":"https:\/\/mht-experience.ro\/"},{"@type":"ListItem","position":2,"name":"Mindspace Victoriei TCI Tower"}]},{"@type":"WebSite","@id":"https:\/\/mht-experience.ro\/#website","url":"https:\/\/mht-experience.ro\/","name":"MHT Experience","description":"Instala\u021bii Electrice","publisher":{"@id":"https:\/\/mht-experience.ro\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/mht-experience.ro\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/mht-experience.ro\/#organization","name":"MHT Experience","url":"https:\/\/mht-experience.ro\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/mht-experience.ro\/#\/schema\/logo\/image\/","url":"https:\/\/mht-experience.ro\/wp-content\/uploads\/2022\/02\/mht-experience-simple-blue.svg","contentUrl":"https:\/\/mht-experience.ro\/wp-content\/uploads\/2022\/02\/mht-experience-simple-blue.svg","width":512,"height":154,"caption":"MHT Experience"},"image":{"@id":"https:\/\/mht-experience.ro\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/MHTexperience\/","https:\/\/www.linkedin.com\/company\/sc-mht-experience-srl-d"]},{"@type":"Person","@id":"https:\/\/mht-experience.ro\/#\/schema\/person\/078400ee203d5f5a5bfb135a8d126e59","name":"Muug Design","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/secure.gravatar.com\/avatar\/639a82f2d6018b07ddb3bbd331072f4c30087d1abc554894590a04495eb8283c?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/639a82f2d6018b07ddb3bbd331072f4c30087d1abc554894590a04495eb8283c?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/639a82f2d6018b07ddb3bbd331072f4c30087d1abc554894590a04495eb8283c?s=96&d=mm&r=g","caption":"Muug Design"},"sameAs":["https:\/\/mht-experience.ro"],"url":"https:\/\/mht-experience.ro\/en\/author\/george-tone\/"}]}},"_links":{"self":[{"href":"https:\/\/mht-experience.ro\/en\/wp-json\/wp\/v2\/posts\/3239","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mht-experience.ro\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mht-experience.ro\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mht-experience.ro\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mht-experience.ro\/en\/wp-json\/wp\/v2\/comments?post=3239"}],"version-history":[{"count":2,"href":"https:\/\/mht-experience.ro\/en\/wp-json\/wp\/v2\/posts\/3239\/revisions"}],"predecessor-version":[{"id":6035,"href":"https:\/\/mht-experience.ro\/en\/wp-json\/wp\/v2\/posts\/3239\/revisions\/6035"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mht-experience.ro\/en\/wp-json\/wp\/v2\/media\/3242"}],"wp:attachment":[{"href":"https:\/\/mht-experience.ro\/en\/wp-json\/wp\/v2\/media?parent=3239"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mht-experience.ro\/en\/wp-json\/wp\/v2\/categories?post=3239"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mht-experience.ro\/en\/wp-json\/wp\/v2\/tags?post=3239"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}